Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters

Database
Language
Document Type
Year range
1.
EClinicalMedicine ; 39: 101066, 2021 Sep.
Article in English | MEDLINE | ID: covidwho-1372972

ABSTRACT

BACKGROUND: Dyspnea and exercise intolerance are commonly reported post-acute sequelae of SARS-CoV-2 infection (PASC), but routine diagnostic testing is often normal. Cardiopulmonary exercise testing (CPET) offers comprehensive assessment of dyspnea to characterize pulmonary PASC. METHODS: We performed a retrospective cohort study of CPET performed on patients reporting dyspnea and/or exercise intolerance following confirmed Covid-19 between August 1, 2020 and March 1, 2021, and compared them to age- and sex-matched patients with unexplained dyspnea referred for CPET at the same center in the pre-Covid-19 era. FINDINGS: Compared to matched unexplained dyspnea comparators, PASC patients shared similar medical comorbidities and subjective dyspnea at referral (mMRC score 1.6 ± 0.9 vs. 1.4 ± 0.9, P = 0.5). Fifteen (83.3%) PASC patients underwent high resolution computed tomography of the chest, of which half (46.7%) were normal, and 17 (94.4%) patients had pulmonary function testing, of which the majority (76.5%) were normal. All patients underwent CPET, and 12 (67%) had normal findings. Compared to matched comparators, PASC patients had similar peak oxygen consumption, oxygen consumption at ventilatory anaerobic threshold, and ventilatory efficiency measured by the minute ventilation to carbon dioxide production (VE/VCO2) slope. INTERPRETATION: Despite prominent dyspnea, physiological abnormalities on CPET were mild across a range of initial Covid-19 severity and similar to matched comparators referred for dyspnea without antecedent SARS-CoV-2. FUNDING: The project was supported by the NHLBI (R01HL131029, R01HL151841, U10HL110337, T32HL116275) and a KL2 award (5KL2TR002542-02) from Harvard Catalyst.

2.
J Card Fail ; 27(1): 105-108, 2021 01.
Article in English | MEDLINE | ID: covidwho-963391

ABSTRACT

BACKGROUND: Exercise testing plays an important role in evaluating heart failure prognosis and selecting patients for advanced therapeutic interventions. However, concern for severe acute respiratory syndrome novel coronavirus-2 transmission during exercise testing has markedly curtailed performance of exercise testing during the novel coronavirus disease-2019 pandemic. METHODS AND RESULTS: To examine the feasibility to conducting exercise testing with an in-line filter, 2 healthy volunteer subjects each completed 2 incremental exercise tests, one with discrete stages of increasing resistance and one with a continuous ramp. Each subject performed 1 test with an electrostatic filter in-line with the system measuring gas exchange and air flow, and 1 test without the filter in place. Oxygen uptake and minute ventilation were highly consistent when evaluated with and without use of an electrostatic filter with a >99.9% viral efficiency. CONCLUSIONS: Deployment of a commercially available in-line electrostatic viral filter during cardiopulmonary exercise testing is feasible and provides consistent data compared with testing without a filter.


Subject(s)
COVID-19/epidemiology , COVID-19/prevention & control , Exercise Test/standards , Heart Failure/diagnosis , Heart Failure/epidemiology , Respiratory Protective Devices/standards , Exercise Test/methods , Feasibility Studies , Humans , Male , Oxygen Consumption/physiology , Pandemics , Pulmonary Gas Exchange/physiology , Reproducibility of Results
SELECTION OF CITATIONS
SEARCH DETAIL